home *** CD-ROM | disk | FTP | other *** search
/ The Hacker Chronicles - A…the Computer Underground / The Hacker Chronicles - A Tour of the Computer Underground (P-80 Systems).iso / hack / mish10.txt < prev    next >
Text File  |  1992-03-03  |  8KB  |  215 lines

  1.  
  2.  
  3.  
  4.                    ***************************************
  5.                    *                                     *
  6.                    *        The 1986 COSMOS FILES        *
  7.                    *    PART III: Service Order Input    *
  8.                    *             Written by:             *
  9.                    *                                     *
  10.                    *            SIR WILLIAM              *
  11.                    *              [KOTRT]                *
  12.                    *                                     *
  13.                    ***************************************
  14.  
  15.  
  16.  
  17. The 1986 COSMOS FILE series consists of 6 parts, including the introduction,
  18. covering all major Service Orders, Work Orders, Reports, Facility and Circuit
  19. Alteration, COSMOS-N/PREMIS transactions and a complete list of all the
  20. facility prefixes.  The 1986 file series is intended for the serious COSMOS
  21. hacker.  (Not too serious)
  22.  
  23. NOTE: The content of this material is proprietary and constitutes a trade
  24. secret.  It is furnished pursuant to written agreements or instructions
  25. limiting the extent of its disclosure.  Its further disclosure in any form
  26. without the permission of its owner, Western Electric Co. Inc., is prohibited.
  27. hi ho.
  28.  
  29. DISCLAIMER: I take full responsibility for all deaths, physical injuries,
  30.             emotional stress, and monetary damages as a result of this file.
  31.             Please send all claims to KOTRT Enterprises, P.O. Box 1223-232,
  32.             Wunderland, N. Ireland 928301
  33.  
  34.                    ***************************************
  35.                         INTRO TO SERVICE ORDER INPUT
  36.                    ***************************************
  37.  
  38. Under COSMOS software version 8.X there are new input procedures for SOE's.
  39. Although these are mostly in the area of error handling, they require a bit
  40. of discussion, seperate from the basic input.
  41.  
  42.     Error Handling
  43.     --------------
  44.       Service order transactions interact with the user more frequently in
  45.       REV 8.X.  Each time the transaction is ready for a new input, it will
  46.       respond with and underscore "_" at the beginning of the new line.  This
  47.       indicates that the preceding line is correct.
  48.       If an error does occur, the transaction will respond with an error
  49.       message and prompt for correction.  When an error occurs, you have
  50.       4 choices.
  51.       1.  Re-enter the entire field correctly.
  52.       2.  Enter line-feed to ignore, (checks rest of line)
  53.       3.  Enter a ";" to disregard the present circuit.
  54.       4.  Enter a "." the transaction will disregard all input, and exit.
  55.  
  56.    H-LINE inputs.
  57.    --------------
  58.       H-LINE input for the service order trio SOE/CSA/TSA is being rigidly
  59. defined in 8.0 according to three categories.  These categorys contain
  60. fundamentally different types of order/facility information.
  61.      Category 1: ORD, OT, DD, FDD,J OC, DT, SG, EO, LC
  62.      Category 2: US, FEA, CCF, CAT, BTN, SS, AO, RZ, FR, GP/CG, CTX/CG/MG/NNX,
  63.                  LDN, RTI.
  64.      Category 3: FW, RW
  65.      Category 1 items are primary, once defined they cannot be changed
  66.                 by conflicting category 2, and 3 lines.
  67.  
  68.                          SERVICE ORDER TRANSACTIONS
  69.  
  70.    Transaction         Definition
  71.    ===========      ======================
  72.    SOE              Service Order Input
  73.    TDZ              Telephone Number Assignment lists
  74.    LDZ              Line Equipment Assignment list
  75.    SOH              Service Order withheld
  76.    SOM              Service Order Modification
  77.    SOC              Service Order Cancellation
  78.    SOW              Service Order Withdraw
  79.    SCM              Service Order Completion by MDF
  80.    SCP              Service Order Completion by PAO
  81.    SCA              Service Order Completion - Automatic
  82.    SCF              Service Order Completion for MDF automatic
  83.    SCI              Spare Cable pair inquiry
  84.    CDD              Change Due Date
  85.    BAI              Bridge Lifter Assignment Inquiry
  86.    LAI              Line Equipment Assignment Inquiry
  87.    NAI              Telephone Numbers Assignment Inquiry
  88.    TAI              Tie pair assignment Inquiry
  89.    EDZ              Facility Emergency Assignment list for backup
  90.    MAP              Manual Assignment Parameters
  91.    MAL              Manual Assignment list
  92.    TSW              Total Service Order Withdraw
  93.  
  94.                    ***************************************
  95.                            TRANSACTIONS DEFINED
  96.                    ***************************************
  97.  
  98. SOE - Service Order Establishment
  99.     - Establishes a pending service order.  The types of orders are; NC, CD,
  100.       CH, F, T, SS, RS, R, RF.  Reassociations are treated as change orders.
  101.     - H-lines must contain ORD, DD, and OT.  Optional facilities; FW, RW, FDD
  102.       AO, FR, SG, and either DT or OC.
  103.     - I and O lines may contain; US, FEA, CP, OE, TN, RZ, NNX, PL, TP, TK, BL, #     SE, CON, MR, BTN, RC, RE, RT,STC, STN, STO, CCF, LCC, and RTI.
  104.     - ESS orders requiring coordination by the recent change input center may  #    be flagged with an input of "RW C".
  105. Example of a NC [New Connect]
  106. WC% SOE
  107. H ORD NCXXXXXX/DD 01-01-86/OT NC/FDD 02-05-86/DT AM
  108. _I CP XXXXX-XXXXXX/OE ?/TN ?/US 2FR/FEA RNNL
  109. _.
  110.  
  111. Example of a CD [Complete Disconnect]
  112. WC% SOE
  113. H ORD CDXXXXXX/DD 01-01-85/OT CD
  114. _O TN 534-1822
  115. _.
  116.  
  117. Example of a CH [Change]
  118. WC% SOE
  119. H ORD CHXXXXX/OT CH/DD 01-01-86/TN 534-1822
  120. _O TN 534-1822/STN CO
  121. _I TN ?
  122. _.
  123. Example of SS [Suspension]
  124. WC% SOE
  125. H ORD SSXXXXX/OT SS/DD 01-01-86
  126. _O TN 534-1822/SS SB
  127. _.
  128.  
  129. TDZ - Telephone Number Assignments List
  130.     - List the indicated number of spare directory numbers for a NNX code, and
  131.       directory number type.
  132.     - Up to 25 directory numbers can be specified, using the prefix LC.
  133. Example
  134. WC% TDZ
  135. H NNX 534/TT G/LC 7    (LC can be up to 25)
  136. .
  137. Output example would look similar to this.
  138. **EMERGENCY FACILITY ASSIGNMENT LIST 01-01-86
  139.   RESERVED LINE EQUIPMENT
  140. **NO SPARE LINE EQUIPMENT FOUND
  141.   AVAILABLE DIRECTORY NUMBERS (7)
  142. 534-XXXX
  143. 534-XXXX, etc.
  144. **TRANSACTION COMPLETED
  145.  
  146. SOW - Service Order Withdraw
  147.     - Withdraws most recent version of a service order
  148.     - Order number must refer to the latest version.  The H-line circuit ID
  149.       identifys the order.  Valid circuit identifiers are; TN, XN, PL, CP, OE,
  150.       and TK.
  151. Example
  152. WC% SOW
  153. H ORD NC-XXXXX/TN 534-1822
  154. .
  155.  
  156. SCP - Service Order Completion by PAO
  157.     - Record in the Service Order File the completion of an order by PAO
  158.     - Standard SXX H line input.
  159. Example
  160. WC% H ord CDXXXXXX/TN 534-1822
  161. .
  162.  
  163. SCA - Service Order Completion Automatic
  164.     - Enters final completion on all service orders which have been or are
  165.       not requried to be completed by the MDF, are not in a held, or jeopardy
  166.       status, and are due prior to or on the current date.
  167.     - Two due dates may be entered on the H-line; SCA will complete orders due #     on or between the dates.  Additional options are OT (order type), ORD,
  168.       and SG.
  169. Example
  170. WC% SCA
  171. .          :complete all orders on or before this due date
  172.  
  173. Example2
  174. WC%SCA
  175. H DD 01-01-86/OT NC     :Complete all NC (new connect) orders
  176. .
  177.  
  178.  
  179. CDD - Change Due Date
  180.     - Change due date of a service or frame order
  181.     - I think an example will suffice;
  182. WC% CDD
  183. H ORD CH-XXXXXX/TN 534-1822
  184. I DD 01-01-86
  185. .
  186. output example
  187. **ORD CH-XXXXX  DUE DATE 01-01-86
  188.  
  189.  
  190. NAI - Telephone Number Assignment Inquiry
  191.     - Provides from 1 to 25 spare telephone numbers compatable with the
  192.       input specifications.
  193.     - Input is an H-line with the TN type and NNX or RZ entries. The status of
  194.       the TN supplied will be modified to reserved if ST is specified on the H-#     line.
  195. Example
  196. WC% NAI
  197. H TT X/NNX 534/ST RS
  198. .
  199. this shows first available spare in prefix 534.
  200.  
  201. MAP - Manual Assignment Parameter
  202.     - Permits the PAO to establish the parameters that will constitute the PAO #     Open-of-Day report.
  203. WC% MAP
  204. I NNX 534/ECS 1R/EQF TNNL/LC 50, etc.   (for line equipment)
  205. I NNX 534/TT B/LC 10  (For Telephone numbers of type B, 10)
  206. etc.
  207.  
  208.     ==============================================================
  209.      [C]OPYRIGHT 1986.  KOTRT ENTERPRISES.  WUNDERLAND, S. AFRICA
  210.     ==============================================================
  211.  
  212.  